Electrical Requests Detail (public view)
Permit Number: E3175986
Address
9200 UNIVERSITY CITY BLVD CHARLOTTE
CHARLOTTE Live Remote Inspection
Confirmation # 3175986003 TCO Reinspection
Received Date Feb 12, 2018 Charge Reinspection Fee
Requested Date Feb 12, 2018 TCO Reinspection Fee: $0.00
Requested Through WEB
Email/Text Msg Addr: coronadoelect@gmail.com
Homeowner Priority:
Homeowner Name: Phone: (   )    -    
Result Date Feb 12, 2018
Result Overall Failed
Inspector Booth, Russell
Inspector Phone # (704) 574-8549
Requested Tasks RF
Results
Task Performed Result Billable to GC Affects HFR
Go
RF - Rough Inspection 02 - Failed 1
Inspector Comments
Last Update By Inspectors Notes Chargeable Failure Affects HFR
POSSE system power user Looked at A2 units Electrical RF Trinity 1) 1st floor: 1032, 34, 36, 38, 40, 42, 1059, 61, 63, 65, 67 Defects: 2) Plastic boxes are installed in the ceiling closer than the allowable distance to other boxes; to maintain its horizontal 2hr fire rating 3) Unit 1032, Receptacle spacing, missing receptacle in bedroom 4) Unit 1065, Bathroom fans not wired and vanity light boxes not installed 5) Unit 1059, Receptacles boxes in closet not installed 6) Unit 1063, Romex cables installed across gusset plate edges, receptacle box not installed 7) Missing stud guards, corrected during inspection 8) EC needs to review all units for defects and make corrections before 2nd floor will be inspected 1