Building Requests Detail (public view)
Permit Number: B3199295
Address 9200 UNIVERSITY CITY BLVD CHARLOTTE
CHARLOTTE
Live Remote Inspection
Confirmation # 3199295019 TCO Reinspection
Received Date Oct 17, 2018 Charge Reinspection Fee
Requested Date Oct 17, 2018 TCO Reinspection Fee: $0.00
Requested Through WEB
Email/Text Msg Addr: Lonny@spireusa.net
Homeowner Priority:
Homeowner Name: Phone: (   )    -    
Result Date Oct 17, 2018
Result Overall Failed
Inspector Koprivica, Milan
Inspector Phone # (704) 582-9481
Requested Tasks FR
mecksectionheading
OTI Start Time: (None)
OTI Duration:
hrs
OTI Extend Hrs: hr(s) OTI Extension Fee: $0.00
Accept OTI Extension Reject OTI Extension
Results
Task Performed Result Partial Approval Note Billable to GC Affects HFR
Go
FR - Framing 02 - Failed 1
Inspector Comments
Last Update By Inspectors Notes Chargeable Failure Affects HFR
Koprivica, Milan C3 shell walkway framing and firestop. Wrong permit called in - this is not upfit permit C3 Garage walkway firestop not completed at firewall and interior side fire barrier. Fire barrier interior side not completed up to underside cannot confirm with fire caulking splattered joints Please re-evaluate interior wall construction Also Pre walk of C3 shell /corridors/ walkway also Corridor opening near garage holes in rated walls 1st & 2nd Exit door from C3 corridors 2nd floor not completed gap between C3 and walkway C3 corridors emergency lights not working Directional arrow at C2 corner exit sign Exit door not latching at garage At 2nd floor no exit signage at walkway Gap joint between walkway and C3 buildings not complete Recheck smoke seals fire doors List is not comprehensive will need to rewalk shell Also Pre Walked shells A,B,C, Parking Garage. Clubhouse, Fitness Center, Pool courtyard, breezeway and equipment rooms, roofs, elevators require full inspection All Type A roll in showers and transfer showers pending/ need corrections 1
RTAP Level: (None)
RTAP Comments:
Screen ID: 467462