Building Requests Detail (public view)
Permit Number: B3177698
Address 9200 UNIVERSITY CITY BLVD CHARLOTTE
CHARLOTTE
Live Remote Inspection
Confirmation # 3177698030 TCO Reinspection
Received Date Aug 13, 2018 Charge Reinspection Fee
Requested Date Aug 13, 2018 TCO Reinspection Fee: $0.00
Requested Through WEB
Email/Text Msg Addr: Lonny@spireusa.net
Homeowner Priority:
Homeowner Name: Phone: (   )    -    
Result Date Aug 13, 2018
Result Overall Failed
Inspector Koprivica, Milan
Inspector Phone # (704) 582-9481
Requested Tasks FR
mecksectionheading
OTI Start Time: (None)
OTI Duration:
hrs
OTI Extend Hrs: hr(s) OTI Extension Fee: $0.00
Accept OTI Extension Reject OTI Extension
Results
Task Performed Result Partial Approval Note Billable to GC Affects HFR
Go
FR - Framing 02 - Failed 1
Inspector Comments
Last Update By Inspectors Notes Chargeable Failure Affects HFR
POSSE system power user C3 garage entry Bottom beams have metal track framing directly to bottom and are covered with sfrm where track framing has no hat channel or clips for length of beams Openings between walkway of buildings not closed, no expansion joint Top of firewall not closed/completed or firestopped with building C3 or parking garage. Thru penetration not all firestopped sprinkler sleeve. Firewall not complete at top Plumbing penetrations in decking covered with sfrm without viewing of 2hr through firestop penetrations above. Are side box beams-Structural support of floors above or floor stops? Need confirmation. Covered Columns did not verify track connections. 1
RTAP Level: (None)
RTAP Comments:
Screen ID: 467462