Building Requests Detail (public view)
Permit Number: B3177698
Address 9200 UNIVERSITY CITY BLVD CHARLOTTE
CHARLOTTE
Live Remote Inspection
Confirmation # 3177698029 TCO Reinspection
Received Date Aug 6, 2018 Charge Reinspection Fee
Requested Date Aug 7, 2018 TCO Reinspection Fee: $0.00
Requested Through WEB
Email/Text Msg Addr: Lonny@spireusa.net
Homeowner Priority:
Homeowner Name: Phone: (   )    -    
Result Date Aug 7, 2018
Result Overall Failed
Inspector Koprivica, Milan
Inspector Phone # (704) 582-9481
Requested Tasks FR
mecksectionheading
OTI Start Time: (None)
OTI Duration:
hrs
OTI Extend Hrs: hr(s) OTI Extension Fee: $0.00
Accept OTI Extension Reject OTI Extension
Results
Task Performed Result Partial Approval Note Billable to GC Affects HFR
Go
FR - Framing 02 - Failed 1
Inspector Comments
Last Update By Inspectors Notes Chargeable Failure Affects HFR
POSSE system power user C3 garage entry metal framing. Missing sfrm many locations removed on columns and beams Metal Tracks for wall framing attached directly to flanges without clips Attached to columns without clips Hole or missing cmu top of wall separating garage and C3. No firestop2 hr separation Metal Framing needs UL joint detail to protected steel SI would need to reinspect sfrm after joint connections made and tracks not directly attached to flanges Also need to address in clubhouse conditions refer to 704.6. & 704.8 2012 NCBC 1
RTAP Level: (None)
RTAP Comments:
Screen ID: 467462