Building Requests Detail (public view)
Permit Number: B3177681
Address 9200 UNIVERSITY CITY BLVD CHARLOTTE
CHARLOTTE
Live Remote Inspection
Confirmation # 3177681017 TCO Reinspection
Received Date Jul 18, 2018 Charge Reinspection Fee
Requested Date Jul 19, 2018 TCO Reinspection Fee: $0.00
Requested Through WEB
Email/Text Msg Addr: Lonny@spireusa.net
Homeowner Priority:
Homeowner Name: Phone: (   )    -    
Result Date Jul 19, 2018
Result Overall Partial Approval
Inspector Koprivica, Milan
Inspector Phone # (704) 582-9481
Requested Tasks IN
mecksectionheading
OTI Start Time: (None)
OTI Duration:
hrs
OTI Extend Hrs: hr(s) OTI Extension Fee: $0.00
Accept OTI Extension Reject OTI Extension
Results
Task Performed Result Partial Approval Note Billable to GC Affects HFR
Go
IN - Insulation 05 - Partial Approval Scope of task is not complete. 0
Inspector Comments
Last Update By Inspectors Notes Chargeable Failure Affects HFR
Koprivica, Milan insulation ceiling C2 exit passageway 1st Level from Garage stair/C1. Prior to covering above, walls at passageway need to be 2 hour fire barriers to underside of floor and inspected. Recheck ceiling details for 2 hours, Recheck door ratings Both side walls require double layer 0
RTAP Level: (None)
RTAP Comments:
Screen ID: 467462