Building Requests Detail (public view)
Permit Number: B3175306
Address 9200 UNIVERSITY CITY BLVD CHARLOTTE
CHARLOTTE
Live Remote Inspection
Confirmation # 3175306030 TCO Reinspection
Received Date Jun 6, 2018 Charge Reinspection Fee
Requested Date Jun 7, 2018 TCO Reinspection Fee: $0.00
Requested Through WEB
Email/Text Msg Addr: Lonny@spireusa.net
Homeowner Priority:
Homeowner Name: Phone: (   )    -    
Result Date Jun 7, 2018
Result Overall Failed
Inspector Koprivica, Milan
Inspector Phone # (704) 582-9481
Requested Tasks IN
mecksectionheading
OTI Start Time: (None)
OTI Duration:
hrs
OTI Extend Hrs: hr(s) OTI Extension Fee: $0.00
Accept OTI Extension Reject OTI Extension
Results
Task Performed Result Partial Approval Note Billable to GC Affects HFR
Go
IN - Insulation 02 - Failed 0
Inspector Comments
Last Update By Inspectors Notes Chargeable Failure Affects HFR
POSSE system power user wrong permit called in, this is shell permit. See Units A4 upfit 0
RTAP Level: (None)
RTAP Comments:
Screen ID: 467462