Go
FR - Framing 02 - Failed 1
Inspector Comments
Last Update By Inspectors Notes Chargeable Failure Affects HFR
POSSE system power user C3 2215 and also at 3215 truss fixes made F27 but paperwork did not address not matching plans location/ replacement of F84 trusses. Need mineral wool in between 15/17 top and bottom plates draft stop at expansion joint between buildings. Also expansion joint needs to be installed, inspected 1215 Recheck structural was ok. 1