Building Requests Detail (public view)
Permit Number: B3199295
Address 9200 UNIVERSITY CITY BLVD CHARLOTTE
CHARLOTTE
Live Remote Inspection
Confirmation # 3199295005 TCO Reinspection
Received Date May 22, 2018 Charge Reinspection Fee
Requested Date May 23, 2018 TCO Reinspection Fee: $0.00
Requested Through WEB
Email/Text Msg Addr: Lonny@spireusa.net
Homeowner Priority:
Homeowner Name: Phone: (   )    -    
Result Date May 23, 2018
Result Overall Failed
Inspector Koprivica, Milan
Inspector Phone # (704) 582-9481
Requested Tasks FR
mecksectionheading
OTI Start Time: (None)
OTI Duration:
hrs
OTI Extend Hrs: hr(s) OTI Extension Fee: $0.00
Accept OTI Extension Reject OTI Extension
Results
Task Performed Result Partial Approval Note Billable to GC Affects HFR
Go
FR - Framing 02 - Failed 1
Inspector Comments
Last Update By Inspectors Notes Chargeable Failure Affects HFR
POSSE system power user C3 Units 2221-2215 2nd floor. Unit 2221 end wall need EJ pvc at 45 thru FW, also Wall W4 at FW sneed 3(2x4)s at 24? oc. Or provide equivalency from engineer. 15 stack units all floors need 3(2x6) under truss girder, address H4 header sizes missing windows. Add stud pack in SW W3 and at above header at truss. 15/17 stacks all floors glued fingerjoined studs in rated tenant wall not approved all floors 3rd floor 3217 finger joined in tenant rated wall not approved for rated wall. Did not look at 3215,19,21,23 due to time 1
RTAP Level: (None)
RTAP Comments:
Screen ID: 467462