Building Requests Detail (public view)
Permit Number: B3199262
Address 9200 UNIVERSITY CITY BLVD CHARLOTTE
CHARLOTTE
Live Remote Inspection
Confirmation # 3199262017 TCO Reinspection
Received Date May 16, 2018 Charge Reinspection Fee
Requested Date May 17, 2018 TCO Reinspection Fee: $0.00
Requested Through WEB
Email/Text Msg Addr: Lonny@spireusa.net
Homeowner Priority:
Homeowner Name: Phone: (   )    -    
Result Date May 17, 2018
Result Overall Failed
Inspector Koprivica, Milan
Inspector Phone # (704) 582-9481
Requested Tasks FR
mecksectionheading
OTI Start Time: (None)
OTI Duration:
hrs
OTI Extend Hrs: hr(s) OTI Extension Fee: $0.00
Accept OTI Extension Reject OTI Extension
Results
Task Performed Result Partial Approval Note Billable to GC Affects HFR
Go
FR - Framing 02 - Failed 1
Inspector Comments
Last Update By Inspectors Notes Chargeable Failure Affects HFR
POSSE system power user Unit 1201 Door opening J2 needs 2 jack studs 2 Windows J3E needs 3 jack studs H4 window header is H1 split window with J2 both sides and middle, RFI 102. Top plate at shear wall calls out 3 (2x6) and truss girder F77 over door header requires 3 full height studs Need to address w engineer Missing 2 anchor bolts Unit 2201 Need H4 header 3(2x12) Need engineer to address F77 truss girder over door header no full height 3 stud pack and 3(2x6) top plate missing at shear wall side Need 4 pack under truss girder F77 at cmu side wall. Required to address all fixes prior to insulation inspection. 1
RTAP Level: (None)
RTAP Comments:
Screen ID: 467462