Building Requests Detail (public view)
Permit Number: B3829790
Address 9905 UNIVERSITY CITY BLVD CHARLOTTE
CHARLOTTE
Live Remote Inspection
Confirmation # 3829790019 TCO Reinspection
Received Date Aug 12, 2021 Charge Reinspection Fee
Requested Date Aug 13, 2021 TCO Reinspection Fee: $0.00
Requested Through WEB
Email/Text Msg Addr: mortiz@mwbuilders.com
Homeowner Priority:
Homeowner Name: Phone: (   )    -    
Result Date Aug 13, 2021
Result Overall Failed
Inspector Koprivica, Milan
Inspector Phone # (704) 582-9481
Requested Tasks RT
mecksectionheading
OTI Start Time: (None)
OTI Duration:
hrs
OTI Extend Hrs: hr(s) OTI Extension Fee: $0.00
Accept OTI Extension Reject OTI Extension
Results
Task Performed Result Partial Approval Note Billable to GC Affects HFR
Go
RT - Routine 02 - Failed 1
Inspector Comments
Last Update By Inspectors Notes Chargeable Failure Affects HFR
Koprivica, Milan Rough walk units 501-531 Smoke seals unit doors typical missing ~ 10 503 FA box hanging ceiling 507 unit door frame not complete and not rated 518 broken window 524 guard rail less than 42? 525 firecaulk hole ceiling support laundry Need to recheck laundry closet also typical units 529 guard rail less than 42? Need tactile/Braille unit identification signage for all units 1
RTAP Level: (None)
RTAP Comments:
Screen ID: 467462