Welcome
WebPermit 7.4
View Permits
|
Links
|
Sign In
Plumbing Requests Detail (public view)
Submit
Cancel
JavaScript and Session Cookies must be enabled for this Site.
Permit Number:
P3403203
Address
14523 CAROWINDS BLVD CHARLOTTE
Live Remote Inspection
CHARLOTTE
Is RDP Inspection
Confirmation #
3403203023
TCO Reinspection
Received Date
Jul 8, 2019
Charge Reinspection Fee
Requested Date
Jul 9, 2019
TCO Reinspection Fee:
0
Requested Through
WEB
Email/Text Msg Addr:
dward-collado@cam-ful.com
Homeowner Priority:
Homeowner Name:
Phone:
( ) -
Result Date
Jul 9, 2019
Result Overall
Failed
Inspector
Hardin, Jimmy
Inspector Phone #
(704) 634-1400
Requested Tasks
FI
OTI Details
OTI Start Time:
(None)
OTI Duration:
hrs
OTI Extend Hrs:
hr(s)
OTI Extension Fee:
$0.00
Accept OTI Extension
Reject OTI Extension
Results
Task Performed
Result
Billable to GC
Affects HFR
Go
FI - Final Inspection
02 - Failed
0
Inspector Comments
Last Update By
Inspection Notes
Chargeable Failure
Affects HFR
Hardin, Jimmy
Need prv on system 95 psi on bldg. need riser clamp on 3? waste line on 2nd and 3rd floors in mop sink room at elevator. Need trap guard in floor drain on 3rd floor in storage room in women?s rrs. Need min 27? clear underneath on lavs in men?s and women?s restroom on 1st floor. Also need 30? clear between partitions on handicap urinals.
0
RTAP Level:
(None)
RTAP Comments:
Submit
Cancel
Screen ID: 467507